Early detection model of normal and abnormal blood flow using pulse Oximetry non-invasive of pregnant heart rate

Authors

  • Yuli Wahyuni Universitas Pakuan
  • Cantika Zaddana Universitas Pakuan
  • Aries Maesya Universitas Pakuan
  • Ahmad Izzuddin Universitas Pakuan

DOI:

10.33395/sinkron.v7i3.11758

Keywords:

Pregnant Mother, Heart Rate, Fetus, Oximetry, Blood Flow

Abstract

The heart is an important organ in humans as an identification of early examinations in pregnant women carried out by doctors to determine normal and abnormal pregnancies in the fetus. Heart rate or BPM (beats per minute) is a parameter that indicates the condition of a person's heart. The normal human heart rate ranges from 60-100 beats per minute. In pumping blood throughout the body, the heart then holds it back after being cleaned by the lungs and this is closely related to the level of oxygen flowing in the bloodstream. Humans need sufficient oxygen levels in the body to survive. One of the vital monitoring tools for oxygen levels in the human body is pulse oximetry. Pulse oximetry is usually in units or rooms with high and rapid action cases such as the ICU. From these problems, it is necessary to make a research on a diagnostic instrument model for early detection of normal and abnormal blood flow using non-invasive pulse oximetry, a case study of the heart rate of pregnant women which can be identified early through the max 30100 sensor reading in the form of detecting the heart rate and oximeter, then processed by Arduino uno R3 where arduino uno processes data in the form of heart rate and oxymeter readings so that it can be displayed via a 16x2 LCD, the output is the identification of the value of the heart rate and oximeter input so that the normal and abnormal heart rate conditions are known. The purpose of this study is to detect early pregnant women and fetuses with normal or abnormal blood flow using non-invasive pulse oximetry in which case studies are implemented on the heartbeat of pregnant women. The method used in this study uses the hardware programming method by starting with project planning, research, part testing, mechanical design, electrical design, software design, functional test, integration, overall testing and optimization. The measurement results from the MAX30100 sensor are processed on Arduino UNO R3 and displayed on the LCD screen. The system as a whole can work with energy supply from the power supply. After measuring with a comparator that has been calibrated, the average error value of the measurement is 3.32 %.

GS Cited Analysis

Downloads

Download data is not yet available.

References

Adiguna, B., Rizal, A., & Hanafi, U. B. (2007). Aplikasi Pengukuran Denyut Jantung Janin Berbasis Ultrasonic Doppler Fetus Monitor.

Anugrah D, dkk. (2016). Rancang Bangun Pengukur Laju Detak Jantung Berbasis PLC Mikro. Jurnal Electronics, Informatics, and Vocational Education (ELINVO), Volume 1.

Almanjani, F.F., Hasrani, Prihastuti., Ismangil, Agus. (2016). Model Pendeteksi Denyut Janutng Menggunakan Pulse Sensor Berbasis Arduino. Universitas Pakuan.

Arthana, I.K.R., Pradnyana, I.M.A (2017). Perancangan Alat Pendeteksi Detak Jantung Dan Notifikasi Melalui Sms. Seminar Nasional Riset Inovatif 2017, 889–895.

Bimo, A.M., Anip, Febtriko, Diki, Arisandi. (2017). Alat Pendeteksi Kondisi Jantung Menggunakan Arduino Uno dan Pulse Sensor. Universitas Abdurrab.

Chabibah, N., & Laela, E. N. (2017). Perbedaan Frekuensi Denyut Jantung Janin Berdasarkan Paritas Dan Usia Kehamilan. Siklus : Journal Research Midwifery Politeknik Tegal, 6(1), 195–198.

Fachrul Rozie, Ferry Hadary, F. Trias Pontia W. (2016) Rancang Bangun Alat Monitoring Jumlah Denyut Nadi / Jantung Berbasis Android. Jurusan Teknik Elektro, Fakultas Teknik. Universitas Tanjungpura.

Mangasa A.S Manullang. (2017). Mendeteksi Denyut Jantung Dengan Menggunakan Pulse Sensor Pada Arduino Uno Berbasis Android. Universitas Sumatera Utara.

Signorini, M.G., Fanelli, Andrea., Magenes, Giovanni., (2014). Monitoring Fetal Heart Rate During Pregnancy: Contributions Drom Advanced Signal Processing and Wearable Technology.

Wibisono, B. M., Setiawan, A., Fitriawan, H., Sulistyanti, S. R., & Purwiyanti, S. (2018). Rancang Bangun Alat Pendeteksi Detak Jantung Menggunakan Pulse Sensor Berbasis Mikrokontroller. Seminar Nasional Hasil Penelitian Sains, Teknik, Dan Aplikasi Industri, 1–8.

Wohingati, G. W., & Subari, A. (2015). Alat Pengukur Detak Jantung Menggunakan Pulsesensor Berbasis Arduino Uno R3 Yang Diintegrasikan Dengan Bluetooth. Gema Teknologi, 17(2), 65–71.

Yundra, Eppy., Suyanti., Kartini, UT., (2019). Sistem Deteksi Jantung Menggunakan Hybrid Internet Of Things Based On Pulse Sensor. Universitas Negeri Surabaya, Indonesia.

Arantra Putra, Andrey. (2006). “Rancang Bangun Pulse Oximetry Digital Berbasis Mikrokontroler.” Politeknik Elektronika Negeri Surabaya.

R,Yanuardi.(2015). “Rancang Bangun Pulse Oximtry Digital Berbasis Mikrokontroler Atmega 16.” Politeknik Telkom Bandung. Y. Sari, “Fungsi pembentukan hemoglobin pada sel darah merah.” Frank, “Saturasi oksigen,” pp. 1–11, 2010.

N. Townsend, “Pulse Oximetry” Medical electronik. 2001.

Downloads


Crossmark Updates

How to Cite

Wahyuni, Y., Zaddana, C. ., Maesya, A. ., & Izzuddin, A. . (2022). Early detection model of normal and abnormal blood flow using pulse Oximetry non-invasive of pregnant heart rate . Sinkron : Jurnal Dan Penelitian Teknik Informatika, 6(3), 2125-2133. https://doi.org/10.33395/sinkron.v7i3.11758