Analysis of data exchange quality in LORA SX1262 Multipoint Telemetric Communication Network

CASE STUDY IN PDAM SMART DESIGN

Authors

  • Satria Gunawan Zain
  • Iwan Suhardi Jurusan Pendidikan Teknik Elektro, Fakultas Teknik, Universitas Negeri Makassar, Makassar, Indonesia
  • Haslina Jurusan Teknik Informatika dan Komputer, Fakultas Teknik, Universitas Negeri Makassar, Makassar, Indonesia

DOI:

10.33395/sinkron.v8i1.12088

Keywords:

Analysis, Data Communication, LoRa SX1262 Telemetry QoS

Abstract

This study aims to determine the results of the analysis of Quality of Service (QoS) parameter testing using LoRa SX1262 telemetry with a certain distance on Smart PDAM and determine the effectiveness of using LoRa SX1262 telemetry on data exchange on multipoint communication networks. The data collection technique uses observation and documentation techniques to obtain valid test results data. This study uses an quantitative descriptive analytical approach with a standard assessment of the TIPHON QoS parameters on the throughput, delay, packet loss, and RSSI (Received Signal Strength Indicator) values. Based on the results of the analysis of this study, it was found that the data can be received well when the RSSI value is above -90 dBm, the average throughput and packet loss values resulting from data transmission on a digital water meter system is inversely proportional to the amount of bandwidth, the average delay of sending LoRa SX1262 telemetry data using a 115200 baud rate of 513 milliseconds. The conclusion of this study is that multipont communication on digital meter data transmission is effectively used at a maximum distance of 300 meters with a bandwidth of 500 kHz.

GS Cited Analysis

Downloads

Download data is not yet available.

References

Andriana, Sutisna Abdul Rahman. (2020). Perancangan Sistem Telemetri Data Meteorologi Pertanian dengan Menggunakan LoRa secara Realtime. Jurnal Teknik Industri, Arsiterktur, Sipil, Informatika dan Elektro, 17(4), 137–142.

Bhakti, S. Raharjo, and M. Sholeh. (2017). Analisis Kinerja Wireless Point to Point Multipoint Client Bridge dan Repeater pada Frekuensi 2.4 GHz. J. JARKOM, 3(2), 12–21.

Burton. (1987). Telemetry for instrumentation and test systems. J. Phys. E., 20(11), 1302–1311.

Carvalho Silva, J. J. P. C. Rodrigues, A. M. Alberti, P. Solic, and A. L. L. Aquino, (2017). LoRaWAN - A low power WAN protocol for Internet of Things: A review and opportunities. 2017 2nd Int. Multidiscip. Conf. Comput. Energy Sci. Split.

Destiarini and P. W. Kumara. (2019).“Robot Line Follower Berbasis Mikrokontroller Arduino Uno Atmega328,” J. Informanika, 5(1), 18–25.

Edwin and H. Kristiadjie. (2016). Pemantau Pengendali dan Penyampaian Informasi Status Operasi Mesin Secara Otomatis,” Tesla, 18(2), 152–165.

Eridani, D., E. D. Widianto, R. Septiana, E. Y. Indrasto, K. T. Martono, and A. Fauzi. (2018). “Data comparison of NFC PN532 on Wemos Dl and MKR1000 board through MQTT protocol,” Proc. 3rd Int. Conf. Informatics Comput. ICIC, 1–5.

Ghani and Zulkifflee. (2022). “Investigation on Data Acquisition Accuracy for Long Range Communication Using RFM LoRa,” 2022 8th Int. Conf. Control. Decis. Inf. Technol. CoDIT 2022, pp. 320–325.

Harianto, A. B. Setiawan, and A. P. Sari. (2017). Sistem Telemetri Pendeteksi Dini Kerusakan Air Conditioner Kendaraan Dengan Metode Scanning. Pros. SNATIF ke-4, pp. 97–103.

Huo, Y., Dong, X., and Beatty, S. (2020). “Cellular Communications in Ocean Waves for Maritime Internet of Things,” IEEE Internet Things J., 7(10), 9965–9979.

Kodali and K. S. Mahesh. (2019). “Proceedings of the 4th International Conference on Contemporary Computing and Informatics, IC3I 2019,” Proc. 4th Int. Conf. Contemp. Comput. Informatics, IC3I 2019, pp. 404–408.

Kneese. (2013). “The economics of regional water quality management,” Econ. Reg. Water Qual. Manag., 1–215.

Kombo, O. H., S. Kumaran, and A. Bovim. (2021). Design and Application of a Low-Cost, Low- Power, LoRa-GSM, IoT Enabled System for Monitoring of Groundwater Resources with Energy Harvesting Integration. IEEE Access, vol. 9, pp. 128417–128433.

Nurjannah, L. Hasanah, and A. Aminudin. (2016). Analisis Jangkauan Dan Baud Rate Transmisi Data Pada Sistem Telemetri Temperatur Berbasis Mikrokontroler. Wahana Fisika, 1(1), 13-20

Putra, Dimas kusuma, Farid Baskoro, Nur Cholis. (2022). “Prototype Smart Fire System Menggunakan Solenoid Valve dan Kamera ESP32-CAM Berbasis IoT Prototype Smart Fire System Menggunakan Solenoid Valve dan Kamera ESP32-CAM Berbasis IoT” J. Tek. Elektro, 11(1), 8–1.

Ramdani R., I. G. P. W. Wedashwara W, and A. Zubaidi. (2020). “Rancang Bangun Smart Meter System untuk Penggunaan Air pada Rumah Tangga Berbasis Internet of Things,” J. Comput. Sci. Informatics Eng., 4(2), 149–160.

Semtech. (2017). “SX1261/2 Data Sheet DS.SX1261-2.W.APP,” in Semtech Corporation, no. December, Semtech, pp. 1–107. [Online]. Available: www.semtech.com.

Suharjono, L. N. Rahayu, and R. Afwah. (2015). “Aplikasi Sensor Flow Water Untuk Mengukur Penggunaan Air Pelanggan Secara Digital Serta Pengiriman Data Secara Otomatis Pada PDAM Kota Semarang,” Tek. Elektro, Politek. negeri Semarang, 13(1), 7–12.

Yanziah, S. Soim, and M. M. Rose. (2020). “Analisis Jarak Jangkauan Lora Dengan Parameter Rssi Dan Packet Loss Pada Area Urban,” J. Teknol. Technoscientia, 13(1), 27–34.

Z. Li and Y. Chen. (2020). “BLE2LoRa: Cross-Technology Communication from Bluetooth to LoRa via Chirp Emulation,” Annu. IEEE Commun. Soc. Conf. Sensor, Mesh Ad Hoc Commun. Networks Work..

Downloads


Crossmark Updates

How to Cite

Zain, S. G. ., Suhardi, I. ., & Haslina. (2023). Analysis of data exchange quality in LORA SX1262 Multipoint Telemetric Communication Network: CASE STUDY IN PDAM SMART DESIGN. Sinkron : Jurnal Dan Penelitian Teknik Informatika, 7(1), 534-543. https://doi.org/10.33395/sinkron.v8i1.12088